BeadChip Molecular Immunohematology (Record no. 105783)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 04411nam a22005295i 4500 |
001 - CONTROL NUMBER | |
control field | 978-1-4419-7512-6 |
003 - CONTROL NUMBER IDENTIFIER | |
control field | DE-He213 |
005 - DATE AND TIME OF LATEST TRANSACTION | |
control field | 20140220083724.0 |
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION | |
fixed length control field | cr nn 008mamaa |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 101125s2011 xxu| s |||| 0|eng d |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
International Standard Book Number | 9781441975126 |
-- | 978-1-4419-7512-6 |
024 7# - OTHER STANDARD IDENTIFIER | |
Standard number or code | 10.1007/978-1-4419-7512-6 |
Source of number or code | doi |
050 #4 - LIBRARY OF CONGRESS CALL NUMBER | |
Classification number | R-RZ |
072 #7 - SUBJECT CATEGORY CODE | |
Subject category code | MBGR |
Source | bicssc |
072 #7 - SUBJECT CATEGORY CODE | |
Subject category code | MED000000 |
Source | bisacsh |
082 04 - DEWEY DECIMAL CLASSIFICATION NUMBER | |
Classification number | 610 |
Edition number | 23 |
100 1# - MAIN ENTRY--PERSONAL NAME | |
Personal name | Ness, Paul M. |
Relator term | editor. |
245 10 - TITLE STATEMENT | |
Title | BeadChip Molecular Immunohematology |
Medium | [electronic resource] : |
Remainder of title | Toward Routine Donor and Patient Antigen Profiling by DNA Analysis / |
Statement of responsibility, etc | edited by Paul M. Ness, Steve R. Sloan, JoAnn M. Moulds. |
264 #1 - | |
-- | New York, NY : |
-- | Springer New York, |
-- | 2011. |
300 ## - PHYSICAL DESCRIPTION | |
Extent | XXII, 152p. 32 illus., 27 illus. in color. |
Other physical details | online resource. |
336 ## - | |
-- | text |
-- | txt |
-- | rdacontent |
337 ## - | |
-- | computer |
-- | c |
-- | rdamedia |
338 ## - | |
-- | online resource |
-- | cr |
-- | rdacarrier |
347 ## - | |
-- | text file |
-- | |
-- | rda |
505 0# - FORMATTED CONTENTS NOTE | |
Formatted contents note | An overview of the Classical Serological methods: limitations and benefits of serology and DNA testing -- Introduction to Molecular Typing -- The BeadChip System: A Flexible Array Format for Complex Nucleic Acid and Protein Analysis -- Implementation of HEA at Blood Centers: Prescreening, Rare Donors, Inventory Management -- Implementation of HEA BeadChip System at Medical Centers: Providing Extended Matched Units and Eliminating Complex Workups for Patients -- Human Platelet Antigen Genotyping and Diagnosis of Antiplatelet Alloimmunization -- Blood group genotyping by high-throughput DNA-analysis: Application to the Panel National de Référence du CNRGS -- Implementation and Assessment of High-Throughput Donor Typing at the Milan, Italy Immunohematology Reference Laboratory -- Implementation of the BioArray Erythrocyte Antigen (HEA) genotyping System BeadChip™ HEA: The Red Cross of Spain Experience -- Looking Beyond HEA: Matching SCD Patients for RH Variants Marion E Reid*, Christine Halter Hipsky -- Identification of Altered RHD and RHCE Alleles: A Comparison of Manual and Automated Molecular Methods -- Bayesian Classification Algorithms for Automated Allele Assignment. |
520 ## - SUMMARY, ETC. | |
Summary, etc | We have entered the era of molecular immunohematology in which DNA is analyzed to predict red blood cell and platelet phenotypes. Indeed, many laboratories and blood banks across the world have already adopted and implemented molecular techniques. Some fear that serology is now becoming outdated, but immunohematology techniques often supplement the work of serologists, and several leading serology laboratories are the very same ones that were early adopters of molecular immunohematology. This book is a thorough review of molecular immunohematology and is aimed at anyone interested in how it is changing blood bank and transfusion medicine. BeadChip Molecular Immunohematology opens with a history of serology before it provides an overview of gene expression, how genetic variations translate into antigenic differences on the surfaces of cells, and techniques that have been developed to detect genetic variations. It then describes in detail the BeadChip technology developed by BioArray Solutions, the molecular immunohematology system that has been most widely adopted in blood blank laboratories. The remainder of the book focuses on analyses and case studies from around the world to describe how molecular immunohematology is being used in various settings for various purposes. It includes a discussion of the significant advances that have been made to incorporate Rh testing on the BeadChip platform as well as the potential use of that system. |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name as entry element | Medicine. |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name as entry element | Immunology. |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name as entry element | Monoclonal antibodies. |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name as entry element | Medical laboratories. |
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name as entry element | Blood transfusion. |
650 14 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name as entry element | Biomedicine. |
650 24 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name as entry element | Biomedicine general. |
650 24 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name as entry element | Immunology. |
650 24 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name as entry element | Antibodies. |
650 24 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name as entry element | Laboratory Medicine. |
650 24 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name as entry element | Molecular Medicine. |
650 24 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
Topical term or geographic name as entry element | Blood Transfusion Medicine. |
700 1# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Sloan, Steve R. |
Relator term | editor. |
700 1# - ADDED ENTRY--PERSONAL NAME | |
Personal name | Moulds, JoAnn M. |
Relator term | editor. |
710 2# - ADDED ENTRY--CORPORATE NAME | |
Corporate name or jurisdiction name as entry element | SpringerLink (Online service) |
773 0# - HOST ITEM ENTRY | |
Title | Springer eBooks |
776 08 - ADDITIONAL PHYSICAL FORM ENTRY | |
Display text | Printed edition: |
International Standard Book Number | 9781441975119 |
856 40 - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | http://dx.doi.org/10.1007/978-1-4419-7512-6 |
912 ## - | |
-- | ZDB-2-SBL |
No items available.